Reference
Quickler guide · Quickler Ltd

UK compliance and inspection frequency guide.

How often each regular check is usually done, by sector, with the regulator named. Most intervals come from your own risk assessment, not a fixed law. Use this as a start and check the current guidance.
IN SHORT

This is a plain reference for how often each regular UK check is usually done, by sector, with the regulator named.

Where the law fixes a period, we say so. Where your risk assessment sets it, which is most of them, we say that instead of inventing a number. Check the named regulator's current guidance before you set a schedule.

A reference page. No sign-up to read it.
The short version
  • Most UK check frequencies come from risk assessment, not a fixed law. The regulator sets the outcome. Your risk assessment sets the interval.
  • A few are fixed: LOLER examination of a hoist is at least every 6 months, the MOT is yearly, and the DVSA walkaround is before first use each day.
  • Weekly fire alarm test, monthly and yearly emergency lighting, and yearly extinguisher service are long-standing practice under British Standards.
  • PAT has no fixed legal interval. Set it by risk.
  • Food and care frequencies mostly sit in your HACCP plan or care risk assessments.
  • Use this page as a start. Check every item against the regulator's current guidance.
Usual frequencies, not legal minimums

Most checks come from a duty to keep something safe, not from one legal number. The regulator sets the outcome. Your written risk assessment sets the interval. Where the law does fix a period, such as the six-monthly LOLER examination of a hoist or the annual MOT, we say so. Everywhere else we say usual. Check the regulator's current guidance before you set a schedule.

Care homes: CQC, Care Inspectorate, CIW, RQIA

Care homes have duties under the Health and Social Care Act, the Regulatory Reform (Fire Safety) Order 2005, the Health and Safety at Work Act, LOLER, COSHH and the Legionella guidance (HSG274 / ACoP L8). These frequencies are common practice. Your fire, water and equipment risk assessments set the real ones.

Usual regular checks
Fire alarm testTest a different call point each week. This is common practice under BS 5839. The Fire Safety Order says the system must be maintained.Weekly
LOLER hoist examinationA thorough examination of hoists and slings that lift people, at least every 6 months, under LOLER 1998. This is a fixed legal minimum.Six-monthly
Legionella and water temperatureMonthly hot and cold outlet temperature checks are common under HSG274. Your water risk assessment sets the real plan.Risk-assessed
PAT (portable appliances)No fixed legal interval. Annual is common in care. Set it by risk for each type of appliance.Annual
Schools and education estates: DfE, HSE, local authority

Schools have the same fire, legionella, asbestos and electrical duties as any employer. They also have a duty of care to pupils. The DfE good estate management guidance and HSE cover most of it. Playground and PE equipment needs an annual check by a competent person, plus routine visual checks.

Usual regular checks
Fire evacuation drillOne drill each term, three a year, is the usual rhythm in UK schools. The Fire Safety Order requires emergency procedures that people can follow, but it does not set a number of drills.Termly
Fire risk assessment reviewKeep the fire risk assessment up to date. Review it regularly, commonly at least yearly, and after any big change to the building or its use.Annual and review
Playground and PE equipmentA yearly check by a competent person is common practice, with routine visual checks all year.Annual and routine
Asbestos managementWhere there is an asbestos management plan, re-inspect known materials at the interval in the plan. HSE says to review the plan every 12 months, or sooner if needed. The rules are the Control of Asbestos Regulations 2012.Ongoing
Fleet and transport: DVSA, DfT

Operators of goods vehicles and PSVs follow the DVSA Guide to Maintaining Roadworthiness. Two items are firm. The daily walkaround check before first use is required. The annual MOT, or the annual test for lorries and buses, is a fixed legal test. The operator sets safety inspection intervals by vehicle type and use, and must keep to them. DVSA says they normally range from 4 to 13 weeks.

Usual regular checks
Driver walkaround checkThe DVSA guide says a walkaround check must be done every day a commercial vehicle is used, before it is driven. Drivers must report defects.Daily
Safety inspectionThe DVSA guide says 4 to 13 weeks is the normal range, by vehicle age and operating conditions. The operator decides the interval from its own assessment and must keep to it. It is not fixed nationally.Operator-set
MOT or annual testCars and vans need their first MOT by the third anniversary of registration, then every year. Lorries and buses are usually tested every year, the first test 12 months after first registration. This is a fixed legal rule.Annual
TachographDrivers download and check tachograph data on a rolling basis. GOV.UK operator guidance says download driver cards at least every 28 days and vehicle units at least every 90 days. Calibrate every 2 years.As used
Food businesses: FSA, local authority EHO, HACCP

Food businesses must have a food safety system based on HACCP. Smaller firms often use the FSA Safer Food, Better Business pack. The local authority environmental health officer inspects and rates the business. Most day-to-day frequencies sit in the firm's own HACCP plan.

Usual regular checks
Temperature logsFridge, freezer and hot-holding temperatures are usually checked and recorded at least daily. Cooking and cooling temperatures are checked at each service. Your HACCP plan sets this.Daily
Cleaning scheduleA written schedule, daily for food-contact surfaces, with regular deep cleans. The firm's own plan and risk set the frequency.Daily and deep
HACCP reviewReview the system when the menu, process, supplier or premises change. At least yearly is good practice.On change
Allergens and pest controlKeep allergen information correct for every dish (Natasha's law for food prepacked for direct sale). Watch for pests all the time, with contractor visits at a risk-assessed interval.Ongoing
General workplace: HSE

Every UK employer has basic duties under the Health and Safety at Work Act, the Regulatory Reform (Fire Safety) Order 2005, the Electricity at Work Regulations and RIDDOR. They sit on top of any sector list above.

Usual regular checks
Fire extinguisher serviceA yearly basic service by a competent person is common practice under BS 5306, plus monthly visual checks by staff.Annual
Emergency lightingA short function test each month and a full-duration test each year are common practice under BS 5266. The Fire Safety Order says the system must be maintained.Monthly and annual
PAT and fixed wiringNo fixed legal interval for PAT. Set it by risk. Fixed wiring is often inspected (EICR) at up to 5 years for many workplaces, but there is no fixed legal interval for workplaces.Risk-assessed
First aid and RIDDORAssess first aid needs and check the kit often, usually monthly. RIDDOR is not a schedule. Report certain injuries, diseases and dangerous occurrences to the HSE when they happen.Duty
Schedule any of these in WhatsApp.

Quickler can schedule any regular check above. The person on the job gets the questions in WhatsApp and answers on the day, with photos. No new app. £75 per month per phone number & unlimited free dashboard accounts. Start with a 14-day free trial. Everything is unlocked and you need no card to start.

Care homesSector 1

The CQC regulates care in England, the Care Inspectorate in Scotland, CIW in Wales and RQIA in Northern Ireland. HSE, fire and LOLER duties apply on top.

CheckTypical frequencyGoverning body / basis
Fire alarm testWeekly (rotating call point)RRO 2005 / BS 5839
Fire drillCommonly every 6 months, more for night staffCommon practice, set by your fire risk assessment
Fire door checksCommonly every 6 months (quarterly in higher-risk)Common practice, set by your fire risk assessment
Legionella / water temperaturesCommonly monthly outlet temps; regime set by water risk assessmentHSE HSG274 / ACoP L8
LOLER hoist thorough examinationAt least every 6 months (fixed)LOLER 1998
PATCommonly annual; risk-assessed, no fixed intervalElectricity at Work Regs 1989
IPC (infection prevention) auditCommonly monthly to quarterlyCQC / Care Inspectorate expectation
Medication (MAR) auditCommonly monthlyCQC / NICE good practice
Health and safety walkCommonly monthlyHSWA 1974 duty

Care frequencies for IPC, medication and H&S walks are provider policy set to meet the regulator's expectations, not a single legal number. Confirm against your regulator's current guidance.

Scotland: the Care InspectorateScotland

In Scotland the Care Inspectorate regulates care, not the CQC. It has no fixed inspection interval. It inspects on a risk basis, and visits can be unannounced. So you prepare all the time, not to a date. For most "how often" questions here, the answer is "all the time, with evidence on the day".

ActivityTypical frequencyBasis
Self-evaluation against the quality frameworkContinuous, an ongoing expectation (not a once-a-year form)Care Inspectorate quality framework and Health and Social Care Standards
Annual return to the Care InspectorateAnnually, in the window the Care Inspectorate setsCare Inspectorate registration duty
InspectionRisk-based, often unannounced, no fixed intervalCare Inspectorate scrutiny model
Notifiable eventsAs they occur, within the required timescaleCare Inspectorate notifiable events guidance

Frequencies are indicative and the Care Inspectorate updates its guidance; always work from the current published requirements. Quickler is not affiliated with or endorsed by the Care Inspectorate. See our Care Inspectorate compliance software guide for how a Scottish service captures self-evaluation and evidence on the day.

Schools and education estatesSector 2

Schools follow DfE good estate management guidance, HSE duties, and the same fire, legionella and asbestos law as any employer.

CheckTypical frequencyGoverning body / basis
Fire evacuation drillTermly (three a year)Usual school practice
Fire risk assessment reviewCommonly at least annually, and on material changeRRO 2005
Legionella monitoringCommonly monthly temps; regime by water risk assessmentHSE HSG274 / ACoP L8
Asbestos management checkRe-inspection of known ACMs at the plan interval; plan reviewed every 12 months or sooner (HSE)Control of Asbestos Regs 2012
PATCommonly annual; risk-assessedElectricity at Work Regs 1989
Playground / PE equipmentAnnual competent-person inspection plus routine visual checksCommon practice (BS EN 1176)
Emergency lightingMonthly function test plus annual full testBS 5266 / RRO 2005

Termly fire drills and annual playground inspections are established practice rather than a single stated legal number. Confirm with your local authority or trust policy.

Fleet and transportSector 3

Operators follow the DVSA Guide to Maintaining Roadworthiness. Walkaround and MOT are firm. Safety inspection intervals are set by the operator.

CheckTypical frequencyGoverning body / basis
Driver walkaround checkDaily, before first use (fixed expectation)DVSA
Safety inspectionOperator-set interval, commonly every 4 to 13 weeksDVSA guide
MOT / annual testAnnual (fixed)DVSA
Tachograph downloadDriver card at least every 28 days; vehicle unit at least every 90 daysGOV.UK drivers' hours guidance
Tachograph calibrationEvery 2 yearsDVSA / approved centre

The safety-inspection frequency is chosen by the operator from vehicle age, type and use, and the operator must then keep to it. The DVSA guide gives 4 to 13 weeks as the normal range. It is not a single national figure.

Food businessesSector 4

Food businesses run a HACCP-based food safety system, often the FSA Safer Food, Better Business pack. The local authority EHO inspects and rates them.

CheckTypical frequencyGoverning body / basis
Temperature logsAt least daily; cooking / cooling at each serviceFSA / HACCP plan
Cleaning scheduleDaily, with periodic deep cleansFSA / HACCP plan
HACCP reviewOn any change; commonly at least annualRegulation (EC) 852/2004
Allergen checkOngoing; accurate for every dishFSA / Natasha law
Pest controlContinuous monitoring; contractor visits at risk-assessed intervalFSA / HACCP plan

Most food frequencies are set inside your own HACCP plan rather than by a fixed national number. The EHO checks that your plan exists, is followed and is recorded.

General workplaceSector 5

Basic HSE, fire and electrical duties for every UK employer. They sit on top of any sector list above.

CheckTypical frequencyGoverning body / basis
Fire extinguisher serviceAnnual basic service plus monthly visual checkBS 5306 / RRO 2005
Emergency lightingMonthly function test plus annual full-duration testBS 5266 / RRO 2005
Fire alarm testWeekly (rotating call point)BS 5839 / RRO 2005
PATRisk-assessed; no fixed legal intervalElectricity at Work Regs 1989
Fixed wiring (EICR)Often up to every 5 years for many workplaces; no fixed legal intervalElectricity at Work Regs 1989 / BS 7671
First aid provisionNeeds assessed; kit commonly checked monthlyHealth and Safety (First-Aid) Regs 1981
RIDDOR reportingNot a schedule; report reportable events when they occurRIDDOR 2013 / HSE

RIDDOR is a reporting duty, not a recurring check. Specified injuries, occupational diseases and dangerous occurrences must be reported to the HSE within the RIDDOR time limits.

Record the check on the dayKeep a record

Knowing the frequency is half the job. The other half is a dated record that the check happened. Make it at the time, not later from memory.

Quickler can schedule any regular check above in WhatsApp. On the due day the person on the job gets the questions and answers them, with a photo where it helps. You get a dated, photographed record and a web link to share. No new app. No login. Pricing is £75 per month per phone number & unlimited free dashboard accounts, after a 14-day free trial, after a 14-day free trial. See the demo.